ORIGINAL ARTICLE
Year : 2022  |  Volume : 21  |  Issue : 1  |  Page : 89-96

Stability indicating reverse phase (RP)-high-performance liquid chromatography method development and validation for the simultaneous estimation of olanzapine and samidorphan in bulk and tablets


1 Department of Pharmaceutical Sciences, Jawaharlal Nehru Technological University, Anantapur, Ananthapuramu; Department of Pharmacy, Sri G. Pullareddy Govt. Polytechnic, B. Thandrapadu, Kurnool, India
2 Department of Chemistry, Krishna University, Machilipatnam, Krishna District, Andhra Pradesh, India

Correspondence Address:
PhD Hathibelagal Mundarinti Sudheer Kumar
Jawaharlal Nehru Technological University Anantapur, Ananthapuramu and Department of Pharmacy, Sri G. Pullareddy Govt. Polytechnic, B. Thandrapadu, Kurnool, Andhra Pradesh, 518007
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/epj.epj_64_21

Rights and Permissions

Background Patients with schizophrenia are given a combination tablet combining olanzapine (OLA), an atypical antipsychotic and samidorphan (SAM), an opioid receptor antagonist. Objectives In bulk and tablet dosage forms, a stability-indicating reverse phase (RP)-high-performance liquid chromatography technique for the simultaneous determination of OLA and SAM has been developed and validated. Materials and methods The chromatographic analysis was performed using an isocratic mobile phase of 0.1% formic acid in water : methanol : acetonitrile (10 : 40 : 50, v/v) at a flow rate of 0.8 ml/min, and the eluents were monitored at an isosbestic point of 285 nm. Results and conclusion The suggested method’s specificity, precision, accuracy, linearity, and robustness were all validated according as per International Conference on Harmonization guidelines. The method’s stability was validated by forced degradation experiments. Retention times for OLA and SAM were 2.85 and 4.79 min, respectively. The method was found to be precise and accurate. SAM linearity was found to be between 14.0 and 45.0 µg/ml, whereas OLA linearity was found to be between 22.5 and 67.5 µg/ml. The limit of detection (LOD) and limit of quantification (LOQ) of OLA were 2.65 and 8.85 µg/ml, respectively, whereas the LOD and LOQ of SAM were 8.12 and 27.06 µg/ml, respectively. As a result, the suggested high-performance liquid chromatography method for the quantification of OLA and SAM was reliable, repeatable, accurate, and sensitive.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed280    
    Printed4    
    Emailed0    
    PDF Downloaded52    
    Comments [Add]    

Recommend this journal